Answer:
e% = 0.99% this value is within the 5% tolerance given by the manufacturer
Explanation:
Modern manufacturing methods establish a tolerance in order to guarantee homogeneous characteristics in their products, in the case of resistors the tolerance or error is given by
e% = | R_nominal - R_measured | / R_nominal 100
where R_nominal is the one written in the resistance in your barcode, R_measured is the real value read with a multimeter and e% is the tolerance also written in the resistors
let's apply this formula to our case
R_nominal = 10 kΩ = 10000 Ω
R_measured = 100 99 Ω
e% = | 10000 - 10099.1 | / 10000 100
e% = 0.99%
this value is within the 5% tolerance given by the manufacturer